USE OF ANALYTICAL SOLUTION OF FUNCTIONING OF THE "HET" SYSTEM FOR EXPRESS ESTIMATION OF THE EFFICIENCY OF ITS WORK
G.V. Anikin1, A.A. Ishkov2,3
1Earth Cryosphere Institute, Tyumen Scientific Centre SB RAS, Malygina str. 86, Tyumen, 625000, Russia 2Tyumen Industrial University, Volodarskogo str. 38, Tyumen, 625000, Russia 3LLC "PetroTrace", Letnikovskaya str. 10, bldg 4, Moscow, 115114, Russia
Keywords: permafrost, soil, seasonal cooling device, "HET" system, condenser, pipeline, evaporator
Abstract
This paper presents the developed analytical model of the functioning of the system of temperature stabilization of soils of the "HET" type, based on the integral method. The paper presents the solutions of numerical and analytical models for temperature stabilization systems of soils of the "HET" type with different lengths of the evaporating part, as well as for the Arctic cities with different climates - Salekhard, Varandey, Igarka. By comparing the results obtained within the framework of numerical and analytical solutions, it has been concluded that the developed analytical model can be used for an express assessment of the functioning of the system of temperature stabilization of soils of the "HET" type for various design solutions and climatic characteristics.
|