Publishing House SB RAS:

Publishing House SB RAS:

Address of the Publishing House SB RAS:
Morskoy pr. 2, 630090 Novosibirsk, Russia



Advanced Search

Atmospheric and Oceanic Optics

2023 year, number 6

Estimates of the height of rise and buoyancy of smoke plumes from high chimneys of thermal power plants from satellite information

V.F. Raputa1, A.A. Lezhenin1, R.A. Amikishieva2
1Institute of Computational Mathematics and Mathematical Geophysics of the Siberian Branch of the RAS, Novosibirsk, Russia
2Siberian Center of the Federal State Budgetary Institution В«Scientific Research Center of Space Hydrometeorology В«Planeta», Novosibirsk, Russia
Keywords: atmosphere, smoke plume, ascent height, buoyancy flow, satellite imagery

Abstract

Methods for estimating the buoyancy and rise characteristics of atmospheric pollutant emissions from high sources are discussed. They are based on the application of the relations of the theory of similarity and dimension for smoke plumes. Aerological sounding data and satellite images of plumes and their shadows on the earth's surface are used as additional information. The proposed approach to assessiment of the buoyancy flows of smoke plumes and the height of their rise was tested for three large thermal power plants in Siberia. A satisfactory agreement between the results and the normative characteristics of buoyancy flow for the chimneys under consideration has been established.