The model system of ordinary differential equations [1, 2] governing the behavior of a non-uniformly heated fluid in a tilted cavity is used for studying the stability of steady regimes of thermal convection at arbitrary (not small) tilting of the rectangular cavity. The bifurcation curve is constructed, which separates the region of parameters (the Rayleigh number ⎯ the cavity tilting angle) into two regions ⎯ the internal and external ones. In the external region, the system has one stable steady solution, and in the internal region, it has three steady solutions. One of them is always unstable in a monotone way, and two others may be both stable and unstable. The neutral curves are constructed, which determine the boundaries of the incipience of the oscillatory and monotone instabilities.
E.A. Demekhin1, E.M. Shapar2, A.S. Selin3 1 South Scientific Center RAS, Krasnodar, Russia 2 South Scientific Center RAS, Krasnodar, Russia 3 Kuban State University, Krasnodar, Russia
Pages: 243-252
The reaction of the film interface to low-amplitude waviness of the wall was studied. A linearized version of the problem described by the Orr ⎯ Sommerfeld equation was considered; the solution was sought by asymptotic expansion in small parameter 1/Re, and usual spectral problem concerning stability to perturbations of exp[iα(x−ct)] type was solved. According to calculations, for some specially chosen wave numbers α the drift and dispersion effects balance each other, providing zero resulting velocity cR = 0. If we assume that a rigid wall is corrugated with the same α, we can say that stationary waves caused by the wavy wall are in resonance with intrinsic perturbations of the second kind.
M.I. Shilyaev1, A.R. Bogomolov2, P.T. Petrik3 1 Tomsk State University of Architecture and Building 2 Kutateladze Institute of Thermophysics SB RAS 3 Kuzbass State Technical University
Pages: 255-265
The results of theoretical and experimental studies of heat exchange at condensation of motionless steam on a vertical tube placed in a granular layer with different wetting angle are presented. Theoretical dependencies are obtained for the estimate of heat-exchange intensity, which account for the condensate slip on the surfaces of grains, and their satisfactory agreement with experimental data of the authors is shown.
B.P. Avksentyuk1, V.V. Ovchinnikov2 1 Vinnitsa Institute of Trade and Economics of Kiev National University of Trade and Economics, Vinnitsa, Ukraine 2 Kutateladze Institute of Thermophysics SB RAS, Novosibirsk, Russia
Pages: 267-274
The effect of liquid subcooling below the saturation temperature on the third heat transfer crisis was studied experimentally at pool boiling. Experimental data on the threshold values of superheating and heat fluxes, above which the evaporation front and third heat transfer crisis for acetone at subcooling from 0.3 to 10 K are formed, were shown. Formation of evaporation fronts is the necessary, but not sufficient condition for the third heat transfer crisis at subcooling. It was found that formation of a stable vapor film after propagation of condensation fronts over the heater surface is possible at heat fluxes considerably lower than the first critical one.
YU.V. Nemirovsky1, A.P. Yankovsky2 1 Khristianovich Institute of Theoretical and Applied Mechanics SB RAS 2 Khristianovich Institute of Theoretical and Applied Mechanics SB RAS
Pages: 275-289
A thermal conductivity model is proposed for an orthogonally reinforced fiber medium with dispersed hardening of the bonding agent. On its basis, the problem of the design of a composite with a given set of effective thermophysical properties is solved as well as the solutions are derived for some inverse problems of the diagnostics of thermophysical properties of phase materials and the reinforcement structure of a fiber composite from known effective thermophysical characteristics.
Thermal conductivity of ozone-safe liquid refrigerant R507 was studied by the method of high-frequency thermal waves within the temperature range of 297.95 … 332.55 K and pressures from the saturation line up to 3.7 MPa. The estimated errors of temperature, pressure, and thermal conductivity measurements are 0.1 K, 3 kPa, and 1.5 %, correspondingly. Thermal conductivity of liquid R507 was calculated on the saturation line. Approximation dependences for thermal conductivity were derived for the whole range of studied temperatures and pressures and on the saturation line.
The properties of thermal radiation of the axisymmetric systems formed by an absorbing medium are analysed. Analysis of absorption and propagation abilities of the systems with an impermeable boundary on the basis of integral radiation equations is suggested together with absorption, transmission, and reflection abilities of the systems with a boundary permeable for radiation.
The peculiarities of cooling of stationary working hot and cold cathodes are under consideration. Scientific premises of the advisability of the tube electrodes arc-spot scanning are presented. The classification of the scanning methods is given. The assumption has been made that the phenomena of auto-electron emission of electrons in vacuum discharge tubes and in arc chambers of plasmatorches under the pressure equal or above atmospheric are somehow similar. The optimum scanning frequency and achievable values of the end-face tube cathode life-time have been estimated. Owing to the magnetic scanning, the area of the electrode surface, which is swept by the arc spot, increases one order or more, resulting in better cooling and reduced specific erosion. The continuous electrode lifetime becomes several orders longer than it is during the work without scanning.
On the basis of experimental data for a windwheel with large-aspect-ratio (up to 14) cylinders, a method making it possible to determine optimal parameters and main characteristics of a windwheel (power, high-speed) is proposed. Effects due to number of cylinders, their aspect ratio and speed of rotation, stream velocity, and generator load are analysed.
V.YA. Rudyak1, A.V. Minakov2, A.A. Gavrilov3, A.A. Dekterev4 1 Baker Atlas Russian Scientific Center Novosibirsk State University of Civil Engineering 2 Polytechnic Institute of the Siberian Federal University 3 Krasnoyarsk Branch of the Kutateladze Institute of Thermophysics SB RAS 4 Krasnoyarsk Branch of the Kutateladze Institute of Thermophysics SB RAS
Pages: 333-345
A model is proposed, which describes the work of the viscometer sensor of the physical pendulum type. The model enables the obtaining of data on fluid viscosity directly from the measurement of the settling frequency of sensor oscillations or the amplitude of these oscillations. To describe the sensor operation a numerical computational algorithm is developed. This method enables the solution of a wide class of three-dimensional laminar fluid flow problems involving moving solids of arbitrary geometry. The results of testing the proposed numerical technique are presented.